Olympus-OM
[Top] [All Lists]

Re: [OM] Help on M.15V upgrade

Subject: Re: [OM] Help on M.15V upgrade
From: "John Hermanson" <omtech@xxxxxxxxx>
Date: Mon, 26 Mar 2001 09:13:29 -0500
I have stopped offering NiMH conversions until a better selection of higher
capacity batteries are developed.
Anyone who bought NiMH cluster from me in the last 6 months and have found
(as I have) the performance shortcomings, I'll accept the clusters for
credit ($42) toward the original Olympus nicad cluster ($70).

John  Hermanson
___________________________________
http://www.zuiko.com
Camtech, Olympus Service since 1977.
21 South Lane,  Huntington NY 11743-4714
Phone/fax 631-424-2121
Free Olympus Manuals: 1-800-221-3000
___________________________________
----- Original Message -----
From: "Mark Dapoz" <md@xxxxxxxxxxxx>
To: <olympus@xxxxxxxxxxxxxxx>
Sent: Saturday, March 24, 2001 9:53 AM
Subject: Re: [OM] Help on M.15V upgrade


| On Sat, 24 Mar 2001, Tom Scales wrote:
|
| > OK, I'm stuck.  I have the thing disassembled just fine and went to take
| > apart the NiMH.  I expected to find something like rectangular button
| > cells -- meaning cells encased in metal.
| >
| > Instead, I found one big plastic 'outer container' with 7 individual,
very
| > messy, cells inside.  It looks like they just put them all together in
the
| > bigger case.
| >
| > Is this right?  Should they be these wierd cells that leak what I expect
is
| > toxic chemicals all over my hands?  I couldn't find the recommended
Vartas
| > locally, so these are just noname NiMH.  I suspect that is the problem.
|
| The cells in the Varta 9V battery are individual cells which are spot
welded
| together using a U shaped piece of metal.  They can be taken apart very
| easily by breaking the spot weld. What you have sounds very different.
|
| > Also, I noticed in the FAQ that some people use NiMH and some use NiCad.
I
| > understand that the NiCads will do sustained bursts better and that the
NiMH
| > doesn't have the memory effect.  Other than that, what is the advantage
of
| > one over the other.
|
| I've rebuilt several of my packs with NiMH cells and I'll never use them
again.
| The performance of NiMH when used with an MD2 is terrible, especially if
you
| plan to use the rewind feature.  They're ok if you limit yourself to 1 or
2
| sequential frames, but if you're going to do that, why not use a winder.
| I'd recommend finding the original 1/3 AA size NiCd cells and rebuild
using
| that.
| -mark
|
|
| < This message was delivered via the Olympus Mailing List >
| < For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
| < Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
|
|


< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >


<Prev in Thread] Current Thread [Next in Thread>
Sponsored by Tako