Re: [OM] RC dead meter

Subject: Re: [OM] RC dead meter
From: "John Hermanson" <omtech@xxxxxxxxx>
Date: Sun, 22 Oct 2000 18:21:53 -0400
This is in reply to someone who picked up an RC with a dead meter.  Often
the battery contact is insulated from the screw that holds it down, by
corrosion, then the corrosion covers the solder point under the battery box,
flows through the wire like water and corrodes the meter switch which is
mounted to the shutter board.
Sometimes the meter movement itself is open.  Meter itself is hard to find.

John  Hermanson
___________________________________
Camtech, Olympus Service since 1977.
21 South Lane,  Huntington NY 11743-4714