Olympus-OM
[Top] [All Lists]

Re: [OM] OM-1 cleaning information requested / Gunk in viewfinder

Subject: Re: [OM] OM-1 cleaning information requested / Gunk in viewfinder
From: "John Hermanson" <omtech@xxxxxxxxx>
Date: Thu, 6 Jul 2000 17:13:26 -0400
Unless you replace the pentaprism (which is a solid block of glass) you will
have to make do with scraping the old foam/paint/silver off the affected
areas of the prism, and cleaning with alcohol uintil the open glass areas
are less objectional when you look through the finder.
Once they are cleaned the uncoated areas will still reflect light as if
plated.  A black ring will show around the perimeter of the area where the
paint and silver were removed.

John  Hermanson
___________________________________
Camtech, Olympus Service since 1977.
21 South Ln.  Huntington NY 11743-4714
631-424-2121 http://www.zuiko.com
Free Olympus Manuals: 1-800-221-3000
___________________________________
----- Original Message -----
From: James Burris <burrisja@xxxxxxxx>
To: Olympus Mailing List <olympus@xxxxxxxxxxxxxxx>
Sent: Thursday, July 06, 2000 11:31 AM
Subject: [OM] OM-1 cleaning information requested / Gunk in viewfinder


| OK,
|
| I now know that I have to remove the top cover of my OM-1 to clean the
| inside of the prism.  Next question is how?
|
| Any help / advice would be appreciated.
|
| Thanks,
|
| James Burris
|
|
|
| < This message was delivered via the Olympus Mailing List >
| < For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
| < Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >
|


< This message was delivered via the Olympus Mailing List >
< For questions, mailto:owner-olympus@xxxxxxxxxxxxxxx >
< Web Page: http://Zuiko.sls.bc.ca/swright/olympuslist.html >


<Prev in Thread] Current Thread [Next in Thread>
Sponsored by Tako